An adapter ships data from a custom source (PLC, sensor, file, network feed) into one or more MTConnect agents.
MTConnect.NET provides two adapter shapes:
- The standalone adapter application — a configurable executable that reads from a declared input and writes SHDR or MQTT to a declared output.
- The embeddable adapter library —
MTConnect.NET-Applications-Adapter, for building a custom adapter executable.
This page documents the standalone adapter's YAML config plus the agent-side adapter modules that consume it.
Adapter vs Agent: Which Side Is Which
The adapter runs close to the data source, often on the same machine or LAN segment. It speaks the source's native protocol (vendor PLC API, OPC-UA, raw TCP) and translates to MTConnect-compatible SHDR or MQTT lines. The agent runs anywhere reachable from the adapter's output socket.
Standalone Adapter Config
The adapter reads its configuration from adapter.config.yaml.
The two top-level shapes are input: (where data comes from) and output: (where SHDR / MQTT lines go).
input:
type: tcp-csv
hostname: 192.168.1.100
port: 9000
fieldMap:
- field: 0
dataItem: avail
- field: 1
dataItem: x-pos-actual
- field: 2
dataItem: spindle-load
output:
type: shdr
port: 7878
heartbeat: 1000
deviceKey: mill-01
deviceKey
The adapter's device identifier.
Every SHDR line emitted on the adapter's socket is associated with this deviceKey; the agent's shdr-adapter module uses the same deviceKey to route incoming lines to the correct Device in its model.
The deviceKey matches the name attribute on the agent-side Device (or its Id if no Name is set).
input:
The adapter ships built-in input shapes:
type: | Description |
|---|---|
tcp-csv | TCP socket emitting CSV-per-line. fieldMap maps each CSV field to a DataItem. |
tcp-shdr | TCP socket emitting SHDR-formatted lines from an upstream source. |
http-poll | Periodic GET against an HTTP endpoint; expects an MTConnect-shaped response. |
file-tail | Tail a log file; one line per observation. |
python | Run a Python script for each observation; the script returns the value via Python.NET. |
The shape of the input block depends on type:. The tcp-csv example above is the most common; http-poll looks like:
input:
type: http-poll
url: http://192.168.1.100/data
interval: 1000
For a fully custom input, write a class implementing IAdapterInput and use the embeddable adapter library.
output:
The adapter ships two output shapes:
type: | Description |
|---|---|
shdr | TCP server that emits SHDR lines on the configured port. The agent's shdr-adapter module connects to this port. |
mqtt | MQTT client that publishes to an external broker on a per-DataItem topic. |
Example MQTT output:
output:
type: mqtt
server: broker.example.com
port: 1883
topicPrefix: MTConnect/Adapter
username: adapter-01
password: <secret>
When using MQTT output, the corresponding agent-side module is mqtt-adapter rather than shdr-adapter.
heartbeat
For SHDR output, the interval (in milliseconds) at which the adapter sends a heartbeat (* PING\n) to its consumer.
The agent expects a heartbeat at least every heartbeat interval; missed heartbeats trip the connection-loss state machine and force a reconnect.
Default: 1000 ms (1 second).
Agent Side: shdr-adapter Module
For each running adapter, the agent's config declares a corresponding shdr-adapter module instance.
The module connects to the adapter's SHDR output socket and routes incoming lines to the matching Device:
modules:
- shdr-adapter:
deviceKey: mill-01
hostname: localhost
port: 7878
heartbeat: 1000
reconnectInterval: 1000
connectionTimeout: 1000
The full key reference is at Configure modules: SHDR adapter.
Agent Side: mqtt-adapter Module
For MQTT-output adapters, the agent's config declares a corresponding mqtt-adapter module instance:
modules:
- mqtt-adapter:
deviceKey: mill-01
server: broker.example.com
port: 1883
topic: MTConnect/Adapter/mill-01
The full key reference is at Configure modules: MQTT adapter.
SHDR Line Shape
The SHDR protocol is described in MTConnect Standard Part_5.0 (docs.mtconnect.org).
A line is:
<timestamp>|<dataItemKey>|<value>
with optional |key|value repeats for compound observations:
2025-01-01T12:34:56.789Z|avail|AVAILABLE
2025-01-01T12:34:56.789Z|x-pos-actual|12.345
2025-01-01T12:34:56.789Z|spindle-load|45|spindle-load-cond|NORMAL||
The dataItemKey resolves through the agent-side Device's GetDataItemByKey(key) lookup, which checks Id, then Name, then Source.DataItemId, then Source.Value.
Authoring the adapter's fieldMap against the Device's Name attribute (rather than its auto-generated Id) is the most resilient pattern: a model edit that re-assigns IDs does not break the adapter.
A heartbeat line is the literal * PING\n, to which the consumer responds with * PONG <heartbeat-ms>\n per the spec.
Buffering and Reconnect
The adapter buffers outbound lines while disconnected; on reconnect, the adapter does NOT replay the buffered lines.
The agent-side shdr-adapter module emits an UNAVAILABLE observation for every DataItem associated with the adapter when the connection drops, and the agent re-establishes the connection through the reconnectInterval poll loop.
For deployments that cannot tolerate data loss across a disconnect, route the adapter's output through MQTT with a persistent broker (set cleanSession: false on the MQTT client and use a durable topic queue) — the broker absorbs the in-flight messages while either end is offline.
Where to Next
- Configure an Agent — the agent side of the data flow.
- Configure Modules — per-module configuration reference.
- Write an Adapter — a programmatic walk-through.